Tool 2 • Load & Surge Sizing

Appliance Wattage & Backup Sizing Calculator

Separates steady running watts from startup motor surges so you can evaluate continuous inverter headroom realistically.

1. Select Appliances & Running Hours

Check appliances you plan to power, adjust quantity, and customize running watts if you have nameplate readings.

Running W / Typical Surge W
Standard Kitchen Refrigerator 150W run / 600W surge

Compressor typically runs ~30%–45% of the day (~1.2–1.8 kWh/day typical).

Chest Freezer (7 cu. ft.) 100W run / 500W surge

Intermittent cycling; typically 600–900 Wh/day in conditioned spaces.

Wi-Fi Router & Cable/Fiber ONT 25W run / 25W surge

Continuous 24-hour draw (600 Wh/day).

LED Home Lighting (5 Bulbs) 50W run / 50W surge

Evening runtime (300 Wh/day).

CPAP Machine (Without Heated Humidifier) 45W run / 45W surge

Overnight 8-hour sleep duration (360 Wh/day).

Laptop + 27" External Monitor 110W run / 130W surge

Standard 8-hour workday (880 Wh/day).

Microwave Oven (1,000W Cooking Class) 1450W run / 1650W surge

Short 15–30 min cumulative daily heating.

Drip Coffee Maker / Electric Kettle 1200W run / 1200W surge

Short brewing cycle.

1/2 HP Sump Pump 800W run / 2200W surge

Intermittent pumping during storms.

240V Submersible Well Pump (1 HP) 1800W run / 4800W surge

Cumulative pressure-tank refill time.

Portable Air Conditioner (10,000 BTU) 1150W run / 2400W surge

High daily Wh demand (~6,900 Wh for 6 hrs continuous cooling).

RV Roof Air Conditioner (13,500 BTU) 1500W run / 3200W surge

Heavy off-grid load; usually requires 3,800Wh+ expandable capacity.

Electric Space Heater (High Setting) 1500W run / 1500W surge

4,500 Wh consumed in just 3 hours.

Starlink Standard Satellite Kit 65W run / 100W surge

Typical daytime/evening connectivity (~1,040 Wh/day).

+ Add Custom Appliance

If startup surge is unknown, leave it blank — we do not guess a generic motor multiplier. Always verify the appliance nameplate or manufacturer manual before connecting motor loads.

1 Day 2 Days 3 Days
EcoFlow DELTA Pro Ultra high-wattage home backup system
240V Split-Phase Loads Well pumps, HVAC blowers, and listed transfer panels require 240V hardware such as DELTA Pro Ultra or F3800.
Jackery Explorer 5000 Plus Smart Transfer Switch home integration
Circuit-Level Backup Sizing Match startup surge plus steady load to your transfer switch circuits with licensed electrician review.

Calculated Load & Energy Estimate

Total Steady Running Load 225 W
Est. Peak (Max 1 Surge Start) 675 W
Est. Daily Consumption 2,100 Wh/day
Suggested Rated Capacity 2,386–2,692 Wh
Note on Starting Surge: Peak estimate above assumes the largest motor appliance starts while other selected loads run steadily (sum of steady loads + highest single motor surge headroom). Worst-case simultaneous startup of every motor (675 W) is shown for reference only.

Matching Models by Published Continuous & Surge Ratings

Important Limitations: Refrigerator compressors and pumps cycle intermittently; running watts × hours overestimates cyclic fridge Wh unless scaled, while motor locked-rotor amps (LRA) can vary by appliance age. Capacity recommendations reflect an estimated 78%–88% AC conversion range rather than a single universal percentage. This tool provides educational estimates, not professional electrical-system design advice.